INSTALLATION
Location of appliance
The appliance must not be installed in a bed-sitting
room of volume less than 20m
3
or in a bathroom or
shower room. It is essential that the appliance is
positioned as in the enclosed figure i.e. shelves,
wall cabinets and cooker hoods must be fitted a
minimum of 690mm directly above the hob and
400mm above the hob when fitted in line with the
outside of the appliance. If the units are intended to
be fitted adjacent to the appliance but less than
400mm above the hob, then a minimum space of
100mm must be maintained between the sides of
the unit and the appliance (see fig).
If fitted next to or between two base units a
minimum space of 1mm must be left between
each unit and the sides of the appliance. The
levelling feet fitted to the appliance will achieve a
nominal height to hob of 900mm+10mm.
The appliance must be installed in accordance
with EN 1116-1995, regarding the depth of the
superior furniture.
The appliance must be set on a heatproof
floor. The adjustable feet must not be
removed.
L.P.G. cookers or ovens MUST NOT be
installed below ground level, i.e. in a
basement, or aboard any boat, yacht or other
vessel.
The cooking appliance must be fitted with
a stability chain firmly secured to the wall
(see fig).
Ventilation
The room containing the cooker should have an air
supply in accordance with B.S. 5440: Part 2: Current
Editions.
The following requirements for ventilation must
be met.
The cooker should not be installed in a bed sitting
room with a volume of less than 20m
3
, if it is
installed in a room of volume less 5m
3
an air vent of
effective area of 110cm
2
is required; if it is installed
in a room of volume between 5m
3
and 10m
3
, an air
vent of effective area 50cm
2
is required, while if the
volume exceeds 11m
3
no air vent is required.
However, if the room has a door, which opens
directly to the outside, no air vent is required even
when the volume is between 5m
3
and 11m
3
.
If there are other fuel burning appliances in the
same room, B.S. 5440: Part. 2: Current Editions
should be consulted to determine the requisite air
vent requirements.
690
400
min 600
max 400
min 570
690
less than
400
100
Firmly fix
chain to rear
of cooker
Stability hook
Stability chain
Chain to be as short
as possible.